Why Choose SAFTYSWITCH RCBOs Over Regular RCBOs?

SAFTYSWITCH RCBOs provide much more than the basic protection available in regular RCBOs. While standard RCBOs mainly offer leakage, overload, and short circuit protection, SAFTYSWITCH models include advanced electrical safety, monitoring, and voltage protection features designed for modern homes, commercial buildings, and industrial systems.

Why Choose SAFTYSWITCH RCBOs Over Regular RCBOs?

Complete Multi-Layer Protection

Most regular RCBOs provide only:

  • Earth leakage protection
  • Overload protection
  • Short circuit protection

SAFTYSWITCH RCBOs provide additional protections such as:

  • Fire protection
  • Over voltage protection
  • Two phasing protection
  • Neutral return protection
  • Neutral failure protection (three-phase models)
  • G-power protection
  • Adjustable voltage cut-off protection (V3/V5 models)

This gives far better protection for both people and electrical equipment.


Better Human Safety

Earth Leakage Protection

SAFTYSWITCH detects leakage current quickly to reduce the risk of:

  • Electric shock
  • Electrocution
  • Leakage-related accidents

G-Power Protection

Available in selected models, this feature provides additional protection even if the neutral line is missing or faulty (with proper grounding connection).

Most regular RCBOs do not offer this advanced safety feature.


Better Appliance & Equipment Protection

Over Voltage Protection

Voltage fluctuation is a common problem that damages:

  • Air conditioners
  • Refrigerators
  • TVs
  • Computers
  • Industrial machinery

SAFTYSWITCH RCBOs protect appliances from dangerous high voltage conditions.

Adjustable Voltage Cut-Off (DXV3 & FXV5)

Users can manually set the voltage cut-off level:

  • 265V
  • 275V
  • 285V
  • 295V
  • 315V

Regular RCBOs usually do not provide adjustable voltage protection.


Fire Hazard Reduction

Leakage current and overheating wires can cause electrical fires.

SAFTYSWITCH RCBOs trip early during dangerous fault conditions, helping reduce:

  • Wire overheating
  • Insulation failure
  • Electrical fire risks

Advanced Monitoring Features

Selected models provide:

  • Line voltage indication
  • Ampere/current indication
  • LED trip indication
  • Buzzer fault indication

These features help users quickly identify:

  • Voltage problems
  • Overload conditions
  • System faults
  • Power abnormalities

Most regular RCBOs only have a simple trip switch without monitoring functions.


Adjustable Leakage Current Settings

SAFTYSWITCH allows users to select leakage sensitivity:

  • 5mA
  • 10mA
  • 20mA
  • 30mA
  • 50mA
  • 100mA

This provides customized protection for:

  • Homes
  • Offices
  • Factories
  • Sensitive equipment
  • Industrial machinery

Regular RCBOs generally have fixed leakage settings.


Designed for Heavy-Duty Applications

Heavy 80mm² Wire Capacity

Supports larger cable connections for:

  • Industrial panels
  • Heavy electrical loads
  • Commercial systems

Durable Rust-Proof Cabinet

Provides long service life and better reliability in harsh environments.


Smart Safety Features

Self-Testing Function

Allows users to verify the protection system is operating correctly.

Emergency Bypass System

Provides temporary power continuity during critical situations.

Double Safety Lock System

Improves operational safety for home and industrial installations.


Better Protection for Indian Power Conditions

In many areas, electrical systems experience:

  • Voltage fluctuation
  • Neutral failure
  • Improper grounding
  • Two phasing issues

SAFTYSWITCH RCBOs are designed to handle these real-world electrical problems better than standard RCBOs.


Suitable for Multiple Applications

Residential Use

Protects:

  • Family members
  • Home appliances
  • Home wiring

Commercial Use

Protects:

  • Office systems
  • Equipment
  • Business operations

Industrial Use

Protects:

  • Motors
  • Machinery
  • Panels
  • Heavy electrical loads

Simple Comparison

FeatureRegular RCBOSAFTYSWITCH RCBO
Leakage protectionYesYes
Overload protectionYesYes
Short circuit protectionYesYes
Fire protectionLimitedAdvanced
Over voltage protectionUsually NoYes
Adjustable leakage currentUsually NoYes
Voltage monitoringNoAvailable
Ampere monitoringNoAvailable
Neutral failure protectionRareAvailable
G-power protectionNoAvailable
Adjustable voltage cut-offNoAvailable
Emergency bypass systemNoYes
Self-testing functionLimitedYes
Heavy wire capacityStandard80mm²

Conclusion

SAFTYSWITCH RCBOs are not just basic circuit breakers — they are advanced electrical safety systems designed to provide:

  • Better human protection
  • Better appliance protection
  • Better fire safety
  • Better voltage management
  • Better industrial reliability

Compared to regular RCBOs, SAFTYSWITCH offers significantly more protection, monitoring, and safety features, making it a stronger solution for modern electrical systems.

The main difference between the SAFTYSWITCH DXG, DXVI, DXVAI, and DXV3

ALL SINGLE PHASE RCBOS MODEL

The main difference between the SAFTYSWITCH DXG, DXVI, DXVAI, and DXV3 models is the level of monitoring, voltage protection control, and display features they provide. All four are 2-pole single-phase RCBOs (RCCB + MCB) and share core electrical safety protections, but each higher model adds more advanced functions.

Feature / FunctionDXGDXVIDXVAIDXV3
Earth leakage protectionYesYesYesYes
Overload protectionYesYesYesYes
Short circuit protectionYesYesYesYes
Fire protectionYesYesYesYes
RCCB + MCB combined protectionYesYesYesYes
Over voltage protectionYesYesYesAdjustable
G-power protectionYesYesYesYes
Two phasing protectionYesYesYesYes
Neutral return protectionYesYesYesYes
Adjustable leakage current5mA–100mA5mA–100mA5mA–100mA5mA–50mA
Tripping LED indicationYesYesYesYes
Tripping buzzer indicationYesYesYesYes
Emergency bypass systemYesYesYesYes
Self-testing functionYesYesYesYes
Line voltage indication systemNoYesYesNo
Ampere indication systemNoNoYesNo
Adjustable over-voltage cut-offNoNoNoYes
Voltage cut-off settingsFixedFixedFixed265V, 275V, 285V, 295V, 315V
Voltage protection bypass optionNoNoNoYes

SAFTYSWITCH DXG

The DXG is the standard advanced protection model. It provides:

  • Complete electrical protection
  • Adjustable leakage current
  • G-power protection
  • Emergency bypass system
  • LED and buzzer indications

Best suited for:

  • Homes
  • Shops
  • Basic commercial installations
  • General electrical safety applications

SAFTYSWITCH DXVI

The DXVI includes all DXG features plus:

  • Line voltage indication system

This allows users to monitor incoming voltage conditions directly on the device.

Best suited for:

  • Areas with unstable voltage
  • Commercial buildings
  • Users needing voltage monitoring

SAFTYSWITCH DXVAI

The DXVAI is a more advanced monitoring model and includes:

  • Line voltage indication
  • Ampere (current) indication system

This allows monitoring of:

  • Voltage status
  • Load current consumption

Best suited for:

  • Industrial applications
  • Load monitoring
  • Heavy appliance management
  • Commercial electrical panels

SAFTYSWITCH DXV3

The DXV3 focuses on advanced voltage protection instead of display monitoring.

Special features include:

  • Adjustable over-voltage cut-off settings:
    • 265V
    • 275V
    • 285V
    • 295V
    • 315V
  • Voltage protection bypass option

This model is designed for environments with severe voltage fluctuation problems.

Best suited for:

  • Areas with unstable or high voltage
  • Sensitive electronics
  • Air conditioners
  • Industrial equipment
  • Appliance protection applications

Simple Model Comparison Summary

  • DXG → Standard advanced protection model
  • DXVI → DXG + voltage display
  • DXVAI → DXVI + current (ampere) display
  • DXV3 → Advanced adjustable voltage protection model

Which Model Should Be Chosen?

  • For general home safety → DXG
  • For voltage monitoring → DXVI
  • For voltage + load monitoring → DXVAI
  • For unstable voltage conditions and sensitive equipment → DXV3

SAFTYSWITCH FXV5 THREE PHASE RCBOS (RCCB+MCB)

MODEL: FXV5

The SAFTYSWITCH FXV5 is an advanced 4-pole three-phase RCBO (Residual Current Circuit Breaker with Overload Protection) designed for complete electrical safety and advanced voltage protection in industrial, commercial, and heavy-duty three-phase electrical systems. It combines RCCB and MCB protection with adjustable over-voltage control and multiple advanced safety functions.

Main Functions (Protections)

Earth Leakage Protection

Detects leakage current flowing to earth and disconnects the power supply immediately to help prevent electric shock and electrocution.

Overload Protection

Protects electrical wiring from overheating and damage caused by excessive current flow.

Short Circuit Protection

Trips instantly during short circuit conditions to protect wiring, electrical panels, machinery, and connected equipment from severe damage.

Fire Protection

The RCBO trips early during leakage or abnormal electrical fault conditions that may generate heat and cause electrical fire hazards.

Combined RCCB + MCB Protection

The FXV5 combines:

  • RCCB protection → leakage current and electric shock protection
  • MCB protection → overload and short circuit protection

This provides complete electrical protection in one integrated unit.

Individual Circuit Protection

Provides dedicated protection for individual circuits, improving safety and simplifying fault isolation in three-phase systems.

Adjustable Over Voltage Cut-Off Protection

The FXV5 includes adjustable over-voltage cut-off settings that allow users to select the voltage limit according to application requirements:

  • 265V
  • 275V
  • 285V
  • 295V
  • 315V

When voltage exceeds the selected limit, the RCBO disconnects the power supply to protect machinery and electrical equipment from damage.

Special Voltage Protection Bypass Option

Allows temporary bypass of voltage protection during special operating conditions when required.

G-Power Protection

Protects users from electric shock even when the neutral line is absent or faulty.
For proper operation, the ground wire must be connected on the input side.

Two Phasing Protection

Protects three-phase motors and machinery from abnormal phase conditions that may cause overheating, imbalance, or equipment failure.

Neutral Return Protection

Detects unsafe neutral return conditions and disconnects the supply for improved electrical safety.

Neutral Failure Protection

Protects the electrical system from neutral failure conditions originating from the main input source. This helps prevent abnormal voltage fluctuations and protects connected equipment from damage.


Features of SAFTYSWITCH FXV5

Adjustable Leakage Current Settings

The leakage current sensitivity can be adjusted according to application requirements:

  • 5mA
  • 10mA
  • 20mA
  • 30mA
  • 50mA
  • 100mA

This allows flexible protection for industrial, commercial, and sensitive equipment applications.

Double Safety Lock System

Provides enhanced operational safety for both residential and industrial environments.

Manual ON/OFF Tripping Indication System

Clearly indicates whether the RCBO is ON, OFF, or tripped, simplifying monitoring and troubleshooting.

Tripping Buzzer Indication with Auto Cut-Off Timer

An audible buzzer alerts users during tripping conditions and automatically switches off after a set time.

Heavy 80mm² Wire Connection Capacity

Supports heavy-duty cable connections suitable for high-load electrical applications.

Durable Rust-Proof Unique Cabinet Design

Built with a strong corrosion-resistant cabinet for long-lasting durability and reliable operation.

Inbuilt MCB Protection Guard

Provides additional protection and mechanical safety for the internal MCB section.

Emergency Bypass System

Allows temporary bypass operation during critical situations where uninterrupted power supply is necessary.

Self-Testing Functions

Includes built-in testing capability to verify proper operation of the protection system.

Tripping LED Indication

LED indicators provide clear visual indication of trip or fault conditions.

4-Pole Three Phase RCBO

Designed specifically for three-phase electrical systems with integrated:

  • RCCB protection
  • MCB protection
  • Over voltage protection

The FXV5 provides complete three-phase electrical safety with adjustable voltage protection and advanced protection features, making it ideal for industrial plants, commercial buildings, machinery, motors, and heavy electrical applications.

SAFTYSWITCH FXVI THREE PHASE RCBOS (RCCB+MCB)

MODEL: FXVI

The SAFTYSWITCH FXVI is an advanced 4-pole three-phase RCBO (Residual Current Circuit Breaker with Overload Protection) designed to provide complete electrical safety, voltage monitoring, and equipment protection for industrial, commercial, and heavy-duty three-phase electrical systems. It combines RCCB and MCB protection with advanced monitoring and fault protection features in one integrated device.

Main Functions (Protections)

Earth Leakage Protection

Detects leakage current flowing to earth and disconnects the power supply immediately to help prevent electric shock and electrocution.

Overload Protection

Protects electrical wiring from overheating and damage caused by excessive current flow.

Short Circuit Protection

Trips instantly during short circuit conditions to protect wiring, electrical panels, machinery, and connected equipment from severe damage.

Fire Protection

The RCBO trips early during leakage or abnormal fault conditions that may generate heat and cause electrical fire hazards.

Combined RCCB + MCB Protection

The FXVI combines:

  • RCCB protection → leakage current and electric shock protection
  • MCB protection → overload and short circuit protection

This provides complete electrical protection in a single compact unit.

Individual Circuit Protection

Provides dedicated protection for individual circuits, improving safety and simplifying fault isolation.

Over Voltage Protection

Protects connected machinery and electrical equipment from dangerous high-voltage conditions.

Two Phasing Protection

Protects three-phase motors and equipment from abnormal phase conditions that can cause overheating, imbalance, or equipment failure.

Neutral Return Protection

Detects unsafe neutral return conditions and disconnects the supply for improved electrical safety.

Neutral Failure Protection

Protects the system from neutral failure conditions originating from the main input source. This helps prevent abnormal voltage fluctuations and protects connected equipment from damage.


Features of SAFTYSWITCH FXVI

Adjustable Leakage Current Settings

The leakage current sensitivity can be adjusted according to application requirements:

  • 5mA
  • 10mA
  • 20mA
  • 30mA
  • 50mA
  • 100mA

This allows flexible protection for industrial, commercial, and sensitive equipment applications.

Double Safety Lock System

Provides enhanced operational safety for both residential and industrial environments.

Manual ON/OFF Tripping Indication System

Clearly indicates whether the RCBO is ON, OFF, or tripped, simplifying monitoring and troubleshooting.

Tripping Buzzer Indication with Auto Cut-Off Timer

An audible buzzer alerts users during tripping conditions and automatically switches off after a set time.

Heavy 80mm² Wire Connection Capacity

Supports heavy-duty cable connections suitable for high-load electrical applications.

Durable Rust-Proof Unique Cabinet Design

Built with a strong corrosion-resistant cabinet for long-lasting durability and reliable operation.

Inbuilt MCB Protection Guard

Provides additional protection and mechanical safety for the internal MCB section.

Emergency Bypass System

Allows temporary bypass operation during critical situations where uninterrupted power is necessary.

Self-Testing Functions

Includes built-in testing capability to verify proper operation of the protection system.

Tripping LED Indication

LED indicators provide clear visual indication of trip or fault conditions.

Line Voltage Indication System

Displays the incoming line voltage status, helping users monitor the electrical supply condition in real time.

4-Pole Three Phase RCBO

Designed specifically for three-phase electrical systems with integrated:

  • RCCB protection
  • MCB protection
  • Over voltage protection

The FXVI provides complete three-phase electrical safety with advanced voltage monitoring and protection features, making it suitable for industrial plants, commercial buildings, machinery, motors, and heavy electrical applications.

SAFTYSWITCH FXVAI THREE PHASE RCBOS (RCCB+MCB)

MODEL: FXVAI

The SAFTYSWITCH FXVAI is an advanced 4-pole three-phase RCBO (Residual Current Circuit Breaker with Overload Protection) designed for complete electrical safety, system monitoring, and equipment protection in industrial, commercial, and heavy-duty three-phase electrical systems. It combines RCCB and MCB protection with voltage and current monitoring features in one integrated safety device.

Main Functions (Protections)

Earth Leakage Protection

Detects leakage current flowing to earth and disconnects the power supply immediately to help prevent electric shock and electrocution.

Overload Protection

Protects electrical wiring from overheating and damage caused by excessive current flow.

Short Circuit Protection

Trips instantly during short circuit conditions to protect wiring, electrical panels, machinery, and connected equipment from severe damage.

Fire Protection

The RCBO trips early during leakage or abnormal fault conditions that may generate heat and cause electrical fire hazards.

Combined RCCB + MCB Protection

The FXVAI combines:

  • RCCB protection → leakage current and electric shock protection
  • MCB protection → overload and short circuit protection

This provides complete protection in a single compact unit.

Individual Circuit Protection

Provides dedicated protection for individual circuits, improving safety and simplifying fault isolation.

Over Voltage Protection

Protects machinery and electrical equipment from dangerous high-voltage conditions.

Two Phasing Protection

Protects three-phase motors and equipment from abnormal phase conditions that can cause overheating, imbalance, or equipment failure.

Neutral Return Protection

Detects unsafe neutral return conditions and disconnects the supply for improved electrical safety.

Neutral Failure Protection

Protects the system from neutral failure conditions originating from the main input source. This helps prevent abnormal voltage fluctuations and damage to connected equipment.


Features of SAFTYSWITCH FXVAI

Adjustable Leakage Current Settings

The leakage current sensitivity can be adjusted according to application requirements:

  • 5mA
  • 10mA
  • 20mA
  • 30mA
  • 50mA
  • 100mA

This allows flexible protection for industrial, commercial, and sensitive equipment applications.

Double Safety Lock System

Provides enhanced operational safety for both residential and industrial environments.

Manual ON/OFF Tripping Indication System

Clearly indicates whether the RCBO is ON, OFF, or tripped, simplifying monitoring and troubleshooting.

Tripping Buzzer Indication with Auto Cut-Off Timer

An audible buzzer alerts users during tripping conditions and automatically switches off after a set time.

Heavy 80mm² Wire Connection Capacity

Supports heavy-duty cable connections suitable for high electrical load applications.

Durable Rust-Proof Unique Cabinet Design

Built with a strong corrosion-resistant cabinet for long-lasting durability and reliable operation.

Inbuilt MCB Protection Guard

Provides additional protection and mechanical safety for the internal MCB section.

Emergency Bypass System

Allows temporary bypass operation during critical situations where uninterrupted power supply is necessary.

Self-Testing Functions

Includes built-in testing capability to verify proper operation of the protection system.

Tripping LED Indication

LED indicators provide clear visual indication of trip or fault conditions.

Line Voltage & Ampere Indication System

Displays:

  • Line voltage status
  • Current (ampere) status

This helps users monitor electrical supply and load conditions in real time.

4-Pole Three Phase RCBO

Designed specifically for three-phase electrical systems with integrated:

  • RCCB protection
  • MCB protection
  • Over voltage protection

The FXVAI provides complete three-phase electrical safety with advanced monitoring and protection features, making it ideal for industrial plants, commercial buildings, machinery, motors, and heavy electrical applications.

SAFTYSWITCH FXPI THREE PHASE RCBOS (RCCB+MCB)

MODEL: FXPI

The SAFTYSWITCH FXPI is a 4-pole three-phase RCBO (Residual Current Circuit Breaker with Overload Protection) designed to provide complete electrical safety and reliable protection for industrial, commercial, and heavy-duty three-phase electrical systems. It combines RCCB and MCB protection with advanced fault protection features in one compact device.

Main Functions (Protections)

Earth Leakage Protection

Detects leakage current flowing to earth and disconnects the power supply immediately to help prevent electric shock and electrocution.

Overload Protection

Protects electrical wiring from overheating and damage caused by excessive current flow.

Short Circuit Protection

Trips instantly during short circuit conditions to protect wiring, electrical panels, machinery, and connected equipment from severe damage.

Fire Protection

The RCBO trips early during leakage or abnormal fault conditions that may generate heat and lead to electrical fire hazards.

Combined RCCB + MCB Protection

The FXPI combines:

  • RCCB protection → leakage current and electric shock protection
  • MCB protection → overload and short circuit protection

This provides complete electrical protection in a single integrated unit.

Individual Circuit Protection

Provides dedicated protection for individual circuits, improving safety and simplifying fault isolation.

Over Voltage Protection

Protects connected equipment and machinery from dangerous high-voltage conditions.

Two Phasing Protection

Protects three-phase motors and equipment from abnormal phase conditions that can cause overheating, imbalance, or equipment failure.

Neutral Return Protection

Detects unsafe neutral return conditions and disconnects the supply for enhanced electrical safety.

Neutral Failure Protection

Protects the system from neutral failure conditions originating from the main input source. This helps prevent abnormal voltage fluctuations and protects connected equipment from damage.


Features of SAFTYSWITCH FXPI

Adjustable Leakage Current Settings

The leakage current sensitivity can be adjusted according to application requirements:

  • 5mA
  • 10mA
  • 20mA
  • 30mA
  • 50mA
  • 100mA

This allows flexible protection for industrial, commercial, and sensitive equipment applications.

Double Safety Lock System

Provides enhanced operational safety for both residential and industrial environments.

Manual ON/OFF Tripping Indication System

Clearly indicates whether the RCBO is ON, OFF, or tripped, simplifying monitoring and troubleshooting.

Tripping Buzzer Indication with Auto Cut-Off Timer

An audible buzzer alerts users when the RCBO trips and automatically switches off after a set time.

Heavy 80mm² Wire Connection Capacity

Supports heavy-duty cable connections suitable for high electrical load applications.

Durable Rust-Proof Unique Cabinet Design

Built with a strong corrosion-resistant cabinet for long-lasting durability and reliable operation.

Inbuilt MCB Protection Guard

Provides additional protection and mechanical safety for the internal MCB section.

Emergency Bypass System

Allows temporary bypass operation during critical situations where uninterrupted power is necessary.

Self-Testing Functions

Includes built-in testing capability to verify proper operation of the protection system.

Tripping LED Indication

LED indicators provide clear visual indication of trip or fault conditions.

4-Pole Three Phase RCBO

Designed specifically for three-phase electrical systems with integrated:

  • RCCB protection
  • MCB protection
  • Over voltage protection

The FXPI provides complete three-phase electrical safety and advanced protection features, making it suitable for industrial plants, commercial buildings, machinery, motors, and heavy electrical applications.

SAFTYSWITCH DXV3 SINGLE PHASE RCBOS (RCCB+MCB)

MODEL: DXV3

The SAFTYSWITCH DXV3 is an advanced 2-pole single-phase RCBO (Residual Current Circuit Breaker with Overload Protection) designed to provide complete electrical protection with adjustable over-voltage control. It combines RCCB and MCB protection with customizable voltage cut-off settings for enhanced appliance and system safety.

Main Functions (Protections)


Earth Leakage Protection

Detects leakage current flowing to earth and disconnects the power supply immediately to help prevent electric shock and electrocution.

Overload Protection

Protects electrical wiring from overheating and damage caused by excessive current flow.

Short Circuit Protection

Trips instantly during short circuit conditions to protect wiring, distribution panels, and electrical appliances from severe damage.

Fire Protection

The RCBO trips early during leakage or abnormal fault conditions that could create heat and cause electrical fire hazards.

Combined RCCB + MCB Protection

The DXV3 combines:

  • RCCB protection → leakage current and electric shock protection
  • MCB protection → overload and short circuit protection

This provides multiple protections in one compact unit.

Individual Circuit Protection

Provides dedicated protection for individual circuits, improving safety and simplifying fault isolation.

Adjustable Over Voltage Cut-Off Protection

The DXV3 includes adjustable over-voltage protection settings that allow users to select the voltage cut-off level according to application requirements:

  • 265V
  • 275V
  • 285V
  • 295V
  • 315V

When voltage exceeds the selected limit, the RCBO disconnects the supply to protect appliances and equipment.

Special Voltage Protection Bypass Option

Allows users to bypass voltage protection temporarily during special operating conditions when required.

G-Power Protection

Protects users from electric shock even when the neutral line is absent or faulty.
For proper operation, the ground wire must be connected on the input side.

Two Phasing Protection

Protects connected equipment from abnormal phase-neutral conditions that may damage appliances.

Neutral Return Protection

Detects unsafe neutral return conditions and disconnects the supply for enhanced electrical safety.


Features of SAFTYSWITCH DXV3


Adjustable Leakage Current Settings

The leakage current sensitivity can be adjusted according to the desired protection level:

  • 5mA
  • 10mA
  • 20mA
  • 30mA
  • 50mA

This allows customized protection for different electrical applications.

Double Safety Lock System

Provides additional operational safety for both residential and industrial installations.

Manual ON/OFF Tripping Indication System

Clearly displays whether the RCBO is ON, OFF, or tripped for easier monitoring and troubleshooting.

Tripping Buzzer Indication with Auto Cut-Off Timer

An audible buzzer alerts users during fault or tripping conditions and automatically switches off after a set time.

Heavy 80mm² Wire Connection Capacity

Supports heavy-duty wire connections suitable for high electrical load applications.

Durable Rust-Proof Unique Cabinet Design

Built with a strong corrosion-resistant cabinet for long-lasting durability and reliable operation.

Inbuilt MCB Protection Guard

Provides additional safety and mechanical protection for the internal MCB section.

Emergency Bypass System

Allows temporary bypass operation during critical situations where uninterrupted power is necessary.

Self-Testing Functions

Includes built-in testing capability to ensure proper operation of protection systems.

Tripping LED Indication

LED indicators provide clear visual indication of trip or fault conditions.

2-Pole Single Phase RCBO

Designed for single-phase electrical systems with integrated:

  • RCCB protection
  • MCB protection
  • Over voltage protection

The DXV3 provides complete electrical safety with adjustable voltage protection, making it suitable for sensitive appliances and unstable voltage environments.

SAFTYSWITCH DXVAI SINGLE PHASE RCBOS (RCCB+MCB)

MODEL: DXVAI

The SAFTYSWITCH DXVAI is an advanced 2-pole single-phase RCBO (Residual Current Circuit Breaker with Overload Protection) designed to provide complete electrical safety, equipment protection, and system monitoring in residential, commercial, and industrial applications. It combines RCCB and MCB protection with voltage and current indication features.

Main Functions (Protections)


Earth Leakage Protection

Detects leakage current flowing to earth and disconnects the supply immediately to help prevent electric shock and electrocution.

Overload Protection

Protects electrical wiring from overheating and damage caused by excessive current flow.

Short Circuit Protection

Trips instantly during short circuit conditions to protect electrical panels, wiring, and connected appliances from severe damage.

Fire Protection

The RCBO trips early during leakage or fault conditions that may create heat and lead to electrical fire hazards.

Combined RCCB + MCB Protection

The DXVAI combines:

  • RCCB protection → leakage current and shock protection
  • MCB protection → overload and short circuit protection

This provides complete protection in a single compact device.

Individual Circuit Protection

Provides dedicated protection for individual circuits, improving safety and simplifying fault isolation.

Over Voltage Protection

Protects electrical appliances and sensitive equipment from dangerous high-voltage conditions.

G-Power Protection

Protects users from electric shock even when the neutral line is absent or faulty.
For proper operation, the ground wire must be connected on the input side.

Two Phasing Protection

Protects connected equipment from abnormal phase-neutral conditions that can damage appliances.

Neutral Return Protection

Detects unsafe neutral return conditions and disconnects the supply for enhanced electrical safety.


Features of SAFTYSWITCH DXVAI


Adjustable Leakage Current Settings

The leakage current sensitivity can be adjusted according to the required safety level:

  • 5mA
  • 10mA
  • 20mA
  • 30mA
  • 50mA
  • 100mA

This allows flexible protection for different applications and environments.

Double Safety Lock System

Provides additional operational safety for both residential and industrial installations.

Manual ON/OFF Tripping Indication System

Clearly indicates whether the RCBO is ON, OFF, or tripped, making maintenance and troubleshooting easier.

Tripping Buzzer Indication with Auto Cut-Off Timer

An audible buzzer alerts users during fault or tripping conditions and automatically switches off after a set time.

Heavy 80mm² Wire Connection Capacity

Supports heavy-duty wire connections for high-load electrical applications.

Durable Rust-Proof Unique Cabinet Design

Built with a strong, corrosion-resistant cabinet for long-lasting durability and reliable operation.

Inbuilt MCB Protection Guard

Provides extra protection and mechanical safety to the internal MCB section.

Emergency Bypass System

Allows temporary bypass operation during critical situations where uninterrupted power is necessary.

Self-Testing Functions

Includes built-in testing capability to ensure the protection system is functioning correctly.

Tripping LED Indication

LED indicators provide clear visual indication of trip or fault conditions.

Line Voltage & Ampere Indication System

Displays:

  • Line voltage status
  • Current (ampere) status

This helps users monitor electrical supply and load conditions directly from the device.

2-Pole Single Phase RCBO

Designed for single-phase electrical systems with integrated:

  • RCCB protection
  • MCB protection
  • Over voltage protection

The DXVAI provides complete electrical protection along with voltage and current monitoring in a single advanced safety device.

SAFTYSWITCH SINGLE PHASE RCBOS (RCCB+MCB)

MODEL: DXVI

The SAFTYSWITCH DXVI is a 2-pole single-phase RCBO (Residual Current Circuit Breaker with Overload Protection) designed to provide complete electrical protection for residential, commercial, and industrial applications. It combines RCCB and MCB functions with advanced safety and monitoring features.

Main Functions (Protections)


Earth Leakage Protection

Detects leakage current flowing to earth and instantly disconnects the power supply to help prevent electric shock and electrocution.

Overload Protection

Protects electrical wiring from overheating and damage caused by excessive current flow.

Short Circuit Protection

Trips immediately during short circuit faults to protect wiring, electrical panels, and connected appliances from severe damage.

Fire Protection

The RCBO trips early during leakage or abnormal fault conditions that may cause electrical fire hazards.

Combined RCCB + MCB Protection

The DXVI integrates:

  • RCCB protection → leakage current and electric shock protection
  • MCB protection → overload and short circuit protection

This provides multiple protections in one compact device.

Individual Circuit Protection

Each connected circuit receives dedicated protection, improving fault isolation and electrical safety.

Over Voltage Protection

Protects appliances and electrical equipment from dangerous high-voltage conditions.

G-Power Protection

Provides protection against electric shock even when the neutral line is absent or faulty.
For correct operation, the ground wire must be connected on the input side.

Two Phasing Protection

Protects appliances and systems from abnormal phase-neutral supply conditions.

Neutral Return Protection

Detects unsafe neutral return conditions and disconnects the supply for enhanced safety.

Features of SAFTYSWITCH DXVI


Adjustable Leakage Current Settings

The leakage current sensitivity can be adjusted according to safety requirements:

  • 5mA
  • 10mA
  • 20mA
  • 30mA
  • 50mA
  • 100mA

This allows flexible protection for different applications.

Double Safety Lock System

Enhances operational safety for both residential and industrial environments.

Manual ON/OFF Tripping Indication System

Clearly indicates whether the RCBO is ON, OFF, or tripped for easier monitoring and maintenance.

Tripping Buzzer Indication with Auto Cut-Off Timer

An audible buzzer alerts users during tripping conditions and automatically turns off after a set time.

Heavy 80mm² Wire Connection Capacity

Supports large wire sizes for heavy electrical load applications.

Durable Rust-Proof Unique Cabinet Design

Built with a strong, corrosion-resistant cabinet for long-lasting durability and reliability.

Inbuilt MCB Protection Guard

Provides additional safety and mechanical protection to the internal MCB section.

Emergency Bypass System

Allows temporary bypass operation during critical situations where uninterrupted power is required.

Self-Testing Functions

Includes built-in testing capability to verify that protection systems are functioning correctly.

Tripping LED Indication

LED indicators provide clear visual fault and trip status information.

Line Voltage Indication System

Displays the supply line voltage status for easy electrical monitoring.

2-Pole Single Phase RCBO

Designed for single-phase electrical systems with integrated:

  • RCCB protection
  • MCB protection
  • Over voltage protection

This makes the DXVI a complete and advanced electrical safety solution in one device.

SAFTYSWITCH DXG SINGLE PHASE RCBOS (RCCB+MCB)

MODEL: DXG

The SAFTYSWITCH DXG is a 2-pole single-phase RCBO (Residual Current Circuit Breaker with Overload Protection) designed to provide advanced electrical safety for homes, shops, offices, and industrial applications. It combines the functions of an RCCB and MCB in one unit, along with additional voltage and safety protections.

Main Functions (Protections)


Earth Leakage Protection

Detects leakage current flowing to earth and disconnects the power supply immediately. This helps prevent electric shock and electrocution.

Overload Protection

Protects wiring from overheating caused by excessive current draw. This helps prevent wire damage and insulation failure.

Short Circuit Protection

Trips instantly during short circuit conditions to protect electrical wiring, appliances, and distribution panels from severe damage.

Fire Protection

The RCBO trips early during leakage or fault conditions that could generate heat and cause electrical fire hazards.

Combined RCCB + MCB Protection

The DXG combines:

  • RCCB function → leakage/electric shock protection
  • MCB function → overload and short circuit protection

This reduces the need for separate devices and saves panel space.

Individual Circuit Protection

Each connected circuit receives independent protection, improving system safety and fault isolation.

Over Voltage Protection

Protects connected appliances and equipment from dangerous high voltage conditions.

G-Power Protection

Provides shock protection even when the neutral line is absent or faulty.
For proper operation, the ground wire must be connected on the input side.

Two Phasing Protection

Protects appliances from abnormal phase-neutral conditions that can damage electrical equipment.

Neutral Return Protection

Detects unsafe neutral return conditions and disconnects the supply for added safety.

Features of SAFTYSWITCH DXG


Adjustable Leakage Current Settings

The leakage sensitivity can be adjusted according to application requirements:

  • 5mA
  • 10mA
  • 20mA
  • 30mA
  • 50mA
  • 100mA

This allows customization for residential, commercial, or industrial safety levels.

Double Safety Lock System

Provides enhanced operational safety for both home and industrial environments.

Manual ON/OFF Tripping Indication System

Clearly shows whether the RCBO is ON, OFF, or tripped, making troubleshooting easier.

Tripping Buzzer Indication with Auto Cut-Off Timer

An audible buzzer alerts users when tripping occurs, and automatically turns off after a set time.

Heavy 80mm² Wire Connection Capacity

Supports heavy-duty wiring connections for higher load applications.

Durable Rust-Proof Cabinet Design

Built with a strong and corrosion-resistant cabinet for long service life and reliable operation.

Inbuilt MCB Protection Guard

Adds extra mechanical protection to the internal MCB section.

Emergency Bypass System

Allows temporary bypass operation during critical situations when uninterrupted power is necessary.

Self-Testing Functions

Includes built-in testing capability to verify proper protection operation.

Tripping LED Indication

LED indicators provide visual fault/trip status for quick monitoring.

2-Pole Single Phase RCBO

Designed specifically for single-phase electrical systems with integrated:

  • RCCB protection
  • MCB protection
  • Over voltage protection

This makes the DXG a complete electrical safety solution in a single device.